AJAX :: Cascade Dropdowns With Web Methods?
May 10, 2010
I am showing state,city, zipcode in cascaded format. I designed cascade dropdown with asp dropdown list controls. I am loaing the citys & zipcode based on selection index changed.. here when I am selecting city the request is sending to server & its loading citys....
I don't want see post back operation on my page when I am selecting city & zipcode. So I am thinking to use Ajax cascade dropdown list to avoid sending the request for each selection.
If I use Ajax Cascade dropdownlist can i cascade the loading of citys & zipcode without using webservices?
If I use only webmethods for cascade dropdown it will work ?
View 4 Replies
Similar Messages:
Feb 24, 2011
I have three cascading dropdowns on my web page and they work fine. The issue I am facing is that there are other controls on the page which cause a postback and with each postback the cascading drop downs are being re-populated (service methods are called) which is becoming a performnace issue.
View 1 Replies
Jan 4, 2011
I have four fields on my insert form: Server, Farm, Silo and Reason. Farm and Silo populate based on the name of the server that is entered. If I take out the SelectedValue='<%# Bind("value") %> the form doesn't error out, but the fields don't post back to the DB.
<!DOCTYPE html PUBLIC "-//W3C//DTD XHTML 1.0 Transitional//EN" "http://www.w3.org/TR/xhtml1/DTD/xhtml1-transitional.dtd">
<%@ Page Language="C#" %>
<html dir="ltr" xmlns="http://www.w3.org/1999/xhtml"> runat="server">
<meta content="en-us" http-equiv="Content-Language" />
[code]...
View 6 Replies
Dec 6, 2010
I am using panel to hide and display certain controls on a page, On one of my panel i have three drop down, all i want is to make sure that user has selected something from the dropdowns otherwise they cant proceed, i am using the requiredfield validator but its just not working
[Code]....
View 9 Replies
Jan 29, 2011
I am using ajax cascading dropdown list one of my program. my code given below.
<asp:DropDownList ID="drpSeason" runat="server"></asp:DropDownList>
<cc1:CascadingDropDown ID="drpSeason_CascadingDropDown" runat="server" Enabled="True"
TargetControlID="drpSeason" ServicePath="Cascade.asmx" ServiceMethod="GetDropDownCategories" Category="category" PromptText="[Season]"> </cc1:CascadingDropDown>
<asp:DropDownList ID="drpb_SalesNo" runat="server" Width="70px"></asp:DropDownList>
<cc1:CascadingDropDown ID="drpb_SalesNo_CascadingDropDown" runat="server" Enabled="True"
TargetControlID="drpb_SalesNo" ParentControlID="drpSeason" ServicePath="Cascade.asmx"
ServiceMethod="salesNo" Category="Sales" PromptText="[Sale]"> </cc1:CascadingDropDown>
And my webservice code given below:
[Code] ....
My Cascading dropdown list work properly. But when I am trying to save my data by below code:
[Code] ....
My Add button doesn't post back. If I delete my cascading dropdown then my code work properly.
View 5 Replies
Mar 11, 2011
I have 45 dropdown lists in my asp page. There are some methods that I can apply to all of these dropdowns. Is it possible to convert them into an array of dropdowns for ease of use?
View 2 Replies
Dec 23, 2010
I've been working on my first version of an ASP.NET app, using cascading dropdowns. I've got 2 dropdowns on a page.
However, the third major control on the page is a details view. It works fantastic, with the cascading dropdowns, to display information from the second dropdown, and allow the user to edit that data. All well and good. But now, in testing, I suddenly realized that I've got no way of displaying the details view if I want to let the user enter new data, which would show some information in the second drop down.
View 5 Replies
Apr 29, 2010
we have a scenario where there is one dropdown on the page now users can add new dropdowns just below the existing dropdown. how do we add dropdowns on the client side and then access the dropdowns on postback?.
and what type of controls do we need to acheive this.
View 3 Replies
Dec 13, 2010
I'm having a problem with a dropdown throwing an error:
Uncaught Sys.WebForms.PageRequestManagerServerErrorException:
Sys.WebForms.PageRequestManagerServerErrorException: Invalid postback or callback argument. Event validation is enabled using <pages enableEventValidation="true"/> in configuration or <%@ Page EnableEventValidation="true" %> in a page. For security purposes, this feature verifies that arguments to postback or callback events originate from the server control that originally rendered them. If the data is valid and expected, use the ClientScriptManager.RegisterForEventValidation method in order to register the postback or callback data for validation.Only Sometimes.
I am using an updatepanel, with a bunch of dropdowns that have an onchange for Javascript, that use ajax (partial page postback). The problem is: I have two dropdowns at the top (also inside the updatepanel) that let me change the current month or year. Sometimes...they change the page (response.redirect), and sometimes they throw that error above. Also, they are the Only two buttons on the page that aren't doing an "onchange" and then ajax stuff....they are actually posting back the entire page to the server (or trying to).
View 3 Replies
Apr 13, 2010
This has totally spoiled my .net 4 vs2010 realease day happiness. Running Cascading dropdowns using 'webservice' asmx method. Everything worked on .3.5 and i solved the running 'code In page' method with this post. Method error 500 [URL] Thought I was sorted but seems the rules are totaly different for the 'webservice method'. For example where did ToolkitScriptManager come from Ive been using ScriptManager for years. Anyway below is the Webservice and Page code. Ive looked at and tried everything of the forum but all of it is pre .4. This is demo code, the real version has 3 dependant dropdowns and the lookups are used several times so it HAS to be a webservice. My current theroies are:
1. Permissions- dosent makes sense.
2. Something missing in web.config to enable webservices.
3. Something to do with placement of 'System.Web.Script.Services.ScriptService()>'
<%@ Page Language="VB" ValidateRequest="false" AutoEventWireup="false" CodeFile="Default.aspx.vb" Inherits="Default2" %>
<!DOCTYPE html PUBLIC "-//W3C//DTD XHTML 1.0 Transitional//EN" "[URL]">
<%@ Register assembly="AjaxControlToolkit" namespace="AjaxControlToolkit" tagprefix="asp" %>
<html xmlns="[URL]">
<head runat="server">
<title></title>
</head>
<body>
<form id="form1" runat="server">
<asp:ToolkitScriptManager ID="ToolkitScriptManager1" runat="server">
</asp:ToolkitScriptManager>
<asp:DropDownList ID="DDListManufacturer" runat="server" CssClass="ddsearch" Width="140px">
</asp:DropDownList>
<asp:CascadingDropDown ID="DDListManufacturer_CascadingDropDown" runat="server" Category="Manufacturer"
PromptText="Select a manufacturer"
ServiceMethod="WebService.GetDropDownContents"
TargetControlID="DDListManufacturer"
ServicePath="WebService.asmx">
</asp:CascadingDropDown>
</form>
</body>
</html ............................................
View 3 Replies
Aug 13, 2010
I have 3 dropdowns in my VB.Net 3.5 web app. After a user selects a value from the first (let's call it Countries) the second (called States) should populate correspondingly. Dropdown three (cities) should also cascade down after a State is selected. The Countries and States dropdowns have SQL DataSources. The Cities dropdown has to call 2 procs (based on the selected State value) so it does not have a SQLDataSource. My question is, the code below works for Countries and States, however, I cannot ge the Cities to populate...
<asp:DropDownList ID="drpCountries" runat="server" DataTextField="CountryName" DataValueField="CountryId" DataSourceID="sdsCountries" AutoPostBack="true">
</asp:DropDownList>
<asp:SqlDataSource ID="sdsCountries" runat="server" ConnectionString="<%$ ConnectionStrings:MyConnectionString %>"
SelectCommand="SELECT * FROM [Countries] ORDER BY [CountryName] ASC"></asp:SqlDataSource>
<asp:UpdatePanel ID="updStates" runat="server" UpdateMode="Conditional">
<ContentTemplate>
<asp:DropDownList ID="drpStates" runat="server" DataTextField="StateName" DataValueField="StateId" AutoPostBack="true" DataSourceID="sdsStates">
</asp:DropDownList>
</ContentTemplate>
<Triggers>
<asp:AsyncPostBackTrigger ControlID="drpCountries" EventName="SelectedIndexChanged" />
</Triggers>
</asp:UpdatePanel>
<asp:SqlDataSource ID="sdsStates" runat="server" ConnectionString="<%$ ConnectionStrings:MyConnectionString %>"
SelectCommand="SELECT * FROM [states] WHERE StateId = @StateID ORDER BY [StateName] ASC">
<SelectParameters>
<asp:ControlParameter ControlID="drpCountries" Name="StateID" PropertyName="SelectedValue" DefaultValue="" />
</SelectParameters>
</asp:SqlDataSource>
THIS DOES NOT WORK:
<asp:UpdatePanel ID="updCities" runat="server" UpdateMode="Conditional">
<ContentTemplate>
<asp:DropDownList ID="drpCities" runat="server" DataTextField="CityName" DataValueField="CityId" AutoPostBack="true">
</asp:DropDownList>
</ContentTemplate>
<Triggers>
<asp:AsyncPostBackTrigger ControlID="drpStates" EventName="SelectedIndexChanged" />
</Triggers>
</asp:UpdatePanel>
Protected Sub drpStates_DataBinding(ByVal sender As Object, ByVal e As System.EventArgs) _
Handles drpStates.DataBinding
' Call some procs and get a DataSet
drpCities.DataSource = ds
drpCities.DataBind()
End Sub
View 2 Replies
Oct 15, 2010
I have three cascading dropdowns and two of them need to trigger something outside of the dropdowns, so I have OnSelectedIndexChanged events on them. So as to not reload the whole page when these items are triggered, I have all of this in an Update Panel.
Everything works fine -- the only issue that the client doesn't like is that the cascading dropdowns reload on the asynchronous postback.
View 3 Replies
Mar 8, 2010
I've got a bit of a problem UpdatePanelAnimationExtenders. Here's an example of the code structure I have:
[Code]....
Now here's my problem. When dd1 triggers the postback both dd1 and dd2 get disabled (instead of just dd1) and after the request is complete only dd1 gets enabled back. The behaviour is also true the other way around (if dd2 triggers the postback both dropdowns get disabled but only dd2 gets enabled back). I'm not really sure what to make of this.
View 3 Replies
Jul 1, 2010
I have a working version of cascading dropdowns.
the code line that adds each item into dropdown is:
[Code]....
View 1 Replies
Mar 22, 2010
I have a web page devoloped in visual studio 2008.I have 4 dropdowns and a repeater in the page.based on the selection(search criteria) from the dropdowns the repeater value will change and one dropdown selection will bind values to the other dropdown also.Since the page is causing a lot of postback we decided to implement ajax here.I am yet to learn ajax.which ajax control replace dropdowns?
i have already server side code written on all dropdowns.Please give me a good solution which i can implement in less time and reuse my code.One more update: i have a master page used in the project.I am using update panel of ajax which does not work if i use master page.(That means all the dropdown controls and repeater i put it in update panel.But still page postback occurs.)In a normal page(without master page) it works?
View 3 Replies
Mar 7, 2010
I am using cascading dropdown list where the no of dropdowns is created dynamically on the page. The cascading drop downs are contained in a User Control. I need to call a method from the Parent page which will be executed when the values in one of the dropdowns change. The server side event is not firing as I have set AutoPostback property for the dropdownlists to be false. How can i make the Page event fired from the Selected index changed of the dropdowns keeping the autopostback property to be set as false.
View 5 Replies
Aug 5, 2010
I am using Cascade dropdown the basic code which i used write down below i am reading data from xml file for Country,State,City.before sometime it was work fine but now it give me an "undefined" data in state dropdown only.
Basically i make a user control on this page my design code are as follow
[Code]....
and on one aspx page i call this control and put a one webmethod for state dropdown
[Code]....
View 1 Replies
Feb 22, 2010
I am using the Page Methods of Asp.Net Ajax to call the server method by enabling EnabledPageMethods of ScriptManager to "True". Can we return the DataSet using the Page Methods written on server side?
And also I want to know what are the default datatypes that are supported by the Page Methods to return to client?
View 3 Replies
Nov 2, 2010
If I use trigger, I do not need the table to determine cascade update?
View 3 Replies
Aug 16, 2010
I have an extension method as follows:
public static class PageExtensions
{
public static int GetUserId(this Page targetPage)
{
var user = Membership.GetUser(targetPage.User.Identity.Name);
return (int)user.ProviderUserKey;
}
}
Now in a page I need to use this method in a static WebMethod, so I have added another 'extension method' to PageExtensions:
public static int GetUserId()
{
return (int)Membership.GetUser(HttpContext.Current.User.Identity.Name).ProviderUserKey;
}
and I call it as follows in my WebMethod: PageExtensions.GetUserId()
View 1 Replies
Jul 23, 2010
public class CacheHelper { /// <summary> /// Removes object with the specified key. /// </summary> /// <param name="key">The key.</param> [code]....
I have this methods for caching..I need to change this methods to use in aDictionary<string,object>
How do I need to change this code Because I am new to asp.net I am still learning..
View 12 Replies
Mar 8, 2011
I have the following models & mappings (code snippets further below).
One Competition has to have multiple CompetitionAnswers associated with it (multiple choice) from the outset.
At present, using the Fluent NHibernate mappings shown below, when I create a brand new Competition object, populate the properties, then create 3 brand new CompetitionAnswer objects and add them to the CompetitionAnswers property (property on Competition), I would expect to call Save on the session which would INSERT the 1 Competition row and 3 CompetitionAnswer rows to the DB.
However, as soon as I try to call Save on the session, it complains that CompetitionId is null and it can't insert a null into the CompetitionAnswers table for that field - which is right, it shouldn't, however, I assumed that the NHibernate would first create the Competition, then use the newly generated IDENTITY value (CompetitionId) in the CompetitionAnswers table?
[code]....
View 3 Replies
Oct 4, 2010
i have a table that contains 3 forign keys, 2 of them from the same table when i make Delete Rule Cascade,this error message appears
'Customers' table saved successfully
'Order' table
- Unable to create relationship 'FK_Order_Customers1'.
Introducing FOREIGN KEY constraint 'FK_Order_Customers1' on table 'Order' may cause cycles or multiple cascade paths. Specify ON DELETE NO ACTION or ON UPDATE NO ACTION, or modify other FOREIGN KEY constraints. Could not create constraint. See previous errors. what is solution,as i want when i delete data from master table ,all dependent (child) data automatically deleted, so i use Cascade.
View 2 Replies
Sep 5, 2010
I have two combo and one button. child combo fill on basis of parent combo key value. click on parent combo value will change on child combo,click on button show those combo selected text.I can do it bellow in my syntax.i use north wind database.
<div>
<dx:ASPxComboBox ID="ASPxComboBoxParent" runat="server" AutoPostBack="True" OnSelectedIndexChanged="ASPxComboBoxParent_SelectedIndexChanged"
TextField="ShipName" ValueField="OrderID" ValueType="System.Int32">
</dx:ASPxComboBox>
<dx:ASPxComboBox ID="ASPxComboBoxChild" runat="server" TextField="ProductID" ValueField="OrderID"
ValueType="System.Int32">
</dx:ASPxComboBox>
<dx:ASPxButton ID="ASPxButton1" runat="server" OnClick="ASPxButton1_Click" Text="ASPxButton">
</dx:ASPxButton>
<dx:ASPxLabel ID="ASPxLabelMessage" runat="server">
</dx:ASPxLabel>
</div>
C# syntax
protected void Page_Load(object sender, EventArgs e)
{
if (!this.IsPostBack)
{
NorthwindDataContext db=new NorthwindDataContext();
var r=from p in db.Orders
select p;
ASPxComboBoxParent.DataSource = r;
ASPxComboBoxParent.DataBind();
}
}
protected void ASPxComboBoxParent_SelectedIndexChanged(object sender, EventArgs e)
{
NorthwindDataContext db=new NorthwindDataContext();
int a= Convert.ToInt32( ASPxComboBoxParent.SelectedItem.Value);
var r = from p in db.Order_Details
where p.OrderID == a
select p;
ASPxComboBoxChild.DataSource = r;
ASPxComboBoxChild.DataBind();
ASPxComboBoxChild.SelectedIndex = 1;
}
protected void ASPxButton1_Click(object sender, EventArgs e)
{
ASPxLabelMessage.Text = "Parent is" + Convert.ToString(ASPxComboBoxParent.SelectedItem.Text) + "And child is" + Convert.ToString(ASPxComboBoxChild.SelectedItem.Text);
}
After click the parent combo,child combo fill But click on button always get child combo index=0 value event i change the child combo value .Why not value change on button event?
View 1 Replies
Feb 8, 2011
I been looking but I cant find any info on this topic Anyway I got a model that looks like this.
[Code]....
I want to cascade delete a category with all its sub categories but I cant make that reference in the database, not with the option to cascade update or delete. It work fine with pagecontents and all the other I got its just this same table reference. In NHibernate I do the cascade setting hbm or with a better way using the fluent option. How do I go about this task now?
View 1 Replies