AJAX :: DropDownList Blinks On Change Event Fire?
Jun 8, 2010
I am using ajax CascadingDropDown with DropDown List, I am having 2 Dropdown list based on that selection Gridview is displayed. It work perfectly
The problem is when i change the 2nd Dropdown list then both Dropdown list blinks and again load the values.
Below is the code
1st DropDownList
<asp:DropDownList
ID="drdBranch"
CssClass="aspDropDownList"
runat="server"
TabIndex="1"
AutoPostBack="true"
/>
<Ajax:CascadingDropDown
ID="CascadingDropDown1"
runat="server"
TargetControlID="drdBranch" ServiceMethod="GetBranchList"
ServicePath="GetDetail.asmx"
Category="Branch" PromptText="Select
Branch" PromptValue=""
LoadingText="Loading Branch...">
</Ajax:CascadingDropDown>
2nd DropDownList
<asp:DropDownList
ID="drdRM"
CssClass="aspDropDownList"
runat="server"
TabIndex="2"
AutoPostBack="true"
/>
<Ajax:CascadingDropDown
ID="CascadingDropDown2"
runat="server"
TargetControlID="drdRM" ServiceMethod="GetRMList"
ServicePath="GetDetail.asmx"
ParentControlID="drdBranch" Category="RM"
PromptText="Select RM"
LoadingText="Loading RM..."> </Ajax:CascadingDropDown>
View 2 Replies
Similar Messages:
Mar 17, 2010
How can I fire a ModalPopupExtender on the SelectIndexChanged event of a dropdownlist?
I only want it to fire when a particular value is chosen in the list.
I tried leaving the PopupControlID value out and calling .Show() on my extender in the onselectchanged event, but it would not allow me to have a blank PopupControlID. If I set the PopupControlID to the ID of my dropdownlist, the popup fires as soon as I click on the dropdownlist control.
View 7 Replies
Sep 24, 2010
I have write the code in .Net. When I click the Buttun then fired below event.
protected void ddldesignation_SelectedIndexChanged(object sender, EventArgs e)
{
Code.
}
View 1 Replies
Feb 9, 2011
I have a DropDown which is bounded to an ObjectDataSource. On its data bound event, I am adding "--select--" value on the 0 index. I have a LinkButton on the page and on its client click, i am selecting different item on drop down (using JavaScript). Suppose there are 3 items like --select--, option1, option2 and option3 and now on link button's client click i selected option3, now if I select the default value "--select--", it does not fire the SelectedIndexChanged event. If I select any other value then it fires. Why does it not work for the default value?
[code]....
View 1 Replies
Apr 29, 2010
page here in asp.net3.5 with C# i m using a datagrid and have Control textbox in it and now oi want to use the textchanged event of this text box so i can perform opertaion on every text box
View 3 Replies
Mar 25, 2010
I have a web application build on asp.net, the Textbox onchange event not working in chrome? On page load i wrote this code,
textbox1.Attributes.Add("onchange", "SetEditDataFlag();");
SetEditDataFlag() -- it is a javascript function. When I browse the application in chrome then this function is not called when i changed some value on the textbox.Its working properly in IE.
View 1 Replies
Apr 21, 2010
I have some code which fires when user selects an item in dropdownlist. Now i want the same code to fire when i set selectedindex programmatically.
I have tried setting
ddlSystemLevelDCP.SelectedIndex=2;
and this as well
ddlSystemLevelDCP.SelectedValue="2";
None of them fires this event.However when user changes the selection,this event fires.Please tell me what am i missing.
View 1 Replies
Jul 22, 2010
I added dropdownlist & textbox control to gridviewrow dynamically on button click.I bind datatable to dropdownlist programatically & dropdownlist Datatextfield="product" & Datavaluefield="Amount". now my question is: when I select a product in dropdownlist,the corresponding product item "Amount" should display in the textbox. I write in my dropdown event like this:
protected void ddl1_SelectedIndexChanged(object sender, EventArgs e)
{
GridViewRow gridViewRow = (GridViewRow)(((Control)sender).NamingContainer);
DropDownList ddl1 = (DropDownList)gridViewRow.FindControl("ddl1");
TextBox itProductQuantity = (TextBox)gridViewRow.FindControl("itProductQuantity");
itProductQuantity.Text = ((DropDownList)sender).SelectedValue;
}
I call that textbox in Gridview row databound. why event is not firing?
View 3 Replies
Dec 29, 2010
Kindly, see the following image. This is my Gridview with separate paging on the top right of the image. The arrows are Image buttons and the right text box is read only.[URL]
I run my page for the first time everything runs perfect. I move to other pages of the grid still perfect. Then i move to other aspx page and then come back. The page loads perfect with the old page number there still perfect. Now if i press any image button then the text change event fires which should not fire.
Note: i need the text change event as i user randomly enters something in the text box then i have to handle that.
Example:
When i return from the other aspx page then the value in the Page Number text box is lets say 4. Then i press the Back image button and a post back happens. The Value in Text box is still the same 4. Then y the event is firing ???
I am not understanding that why this event is firing. On the page load, i retrieve the values from hash table (The hash table is stored in session in base page) and from the hash table i get the pageNo and assign it to the page No text box.
Here, is my one of the image button event. (Remaining image button events are almost same)
[Code]....
My text box change event.
[Code]....
My page load Code: Note: PageUniqueIdr = PageUniqueId retrieved from the QueryString.
[Code]....
[Code]....
View 5 Replies
Dec 9, 2010
I create a dropDownList in code-behind, in selectIndexChange of another dropDownList, and add this new dropDownList to page using a placerHolder, everthing its ok, but new dropdownlist selectIndexChange event dont fire!
code of dropDownList creation
dropDown = new DropDownList();
dropDown.AutoPostBack = true;
dropDown.ID = idSubistema;
dropDown.Width = 400;
dropDown.CssClass = "controltext";
dropDown.DataValueField = "IDNivel";
dropDown.DataTextField = "NIVEL";
dropDown.EnableViewState = true;
dropDown.DataSource =
DBLibray.DefinitionIndicadores.spSelect_FillCombosWithNivelByIdParent(
ref dataConnector,
Convert.ToInt32(idSubistema));
dropDown.DataBind();
dropDown.SelectedIndexChanged += new EventHandler(indexChange);
//dropDown.PreRender += new EventHandler(dropDown_PreRender);
placeHolderForCombos.Controls.Add(new LiteralControl("<div>"));
placeHolderForCombos.Controls.Add(lb);
placeHolderForCombos.Controls.Add(new LiteralControl("<br>"));
placeHolderForCombos.Controls.Add(dropDown);
placeHolderForCombos.Controls.Add(new LiteralControl("</div>"));
placeHolderForCombos.Controls.Add(new LiteralControl("<br>"));
View 2 Replies
May 7, 2015
I have a gridview and dropdownlist, let say the content of dropdownlist is YEAR and the content of gridview is Name and Year. Now for everytime I change the Value of dropdownlist the content of gridview will change but it will not load the page
View 1 Replies
May 9, 2010
I in page load i change the checkstate of checkbox false to true or true to false, in turn which i expect to fire the check_change state but seems not firing the event
protected void Page_Load(object sender, EventArgs e)
{
chkDegisim.Checked = true;
chkDegisim.Checked = false;
}
protected void chkDegisim_CheckedChanged(object sender, EventArgs e)
{
int a = 1;
}
when i put a breakpoint to chkDegisim_CheckedChanged, it does not fall into the event chkDegisim_CheckedChanged.
chkDegisim's autopostback is true and i have declered chkDegisim_CheckedChanged event in aspx.
why it does not fire chkDegisim_CheckedChanged event?
View 5 Replies
Dec 16, 2013
I am using a dropdownlist in my application and it has corresponding SelectedIndexChanged() event.I would like to invoke GridViewEdit Event when SelectedIndexChanged event fires from dropdown list.Is it possible to implement this...??
<asp:DropDownList ID="ddlStatus" Visible="true" AutoPostBack="true" OnSelectedIndexChanged="ddlStatus_SelectedIndexChanged" runat="server">
</asp:DropDownList>
protected void ddlStatus_SelectedIndexChanged(object sender, EventArgs e)
{
//Code to fire the GridViewEdit Event to put a row in edit mode
}
View 1 Replies
Jun 28, 2010
I have a form which has some dropdownlists (ListItems "Yes" "No"). I use my form to Enter data & submit to database and use same form to Edit aswell. Like I redirect to this form from another page with a QueryString. If there is a QueryString then SELECT * FROM Table WHERE ID = QueryString's value & fill all the controls in the form like
[URL]
I have certain things to do when DropDownList.SelectedValue = "Yes" so I can use SelectedIndexChanged event handler & AutoPostBack="true" when submitting form for the first time. Now when I edit the information(Data filled from table as stated above). How can i automatically fire all events like DropDownlist SelectedIndexChanged in the page_Load iteslef so that all the things that are supposed to be done when DropDownList.SelectedValue = "Yes". I'm posting my test code for reference to explain what I'm trying to do. This is just the Idea. I have something else to deal with if i can get this stright. I need to dynamically add controls based on the values of DropDownList. please suggest some thing guys.
[Code]....
View 6 Replies
Jan 17, 2010
I am trying to get a modal popup inside a modal popup?, also i want to fire the modal popup on a condition in a text change event of a textbox?...is this possible and can anyone give me directon on this
View 5 Replies
Oct 5, 2010
i have a form in asp.net. I want to fire
[Code]....
can we use ajax timer for this if so how can we use it ? or there is any other way for this.
View 2 Replies
Aug 31, 2010
i want to open new window ,but i dont want to provide url link in script because i want to hide this link from user.so is there any method to get URL from server and fire event to open new window after cliking button which has some server logic on that basis serever return URL.
View 4 Replies
Sep 18, 2010
I have a multi view with 2 view in my page. when page is loading first view is set active. by click on a click I set active second view that contain AsyncFileUpload1. but UploadedComplete event doesn't fire. This control works outside of view correctly but into view doesn't work. I have to use multi view and this 2 view in my web page. what can I do?
View 9 Replies
Nov 24, 2010
The problem is simple, it doesn't fire (show the dropdownlist)
Here's all my code related to it.
Inside my masterpage:
[Code]....
I've compared it to many exemples and all is fine
If I test the service directly, it work
View 6 Replies
Apr 6, 2010
how to fire a link button event which is there at ajax tab container?
View 1 Replies
Jan 12, 2011
I have my ReorderList setup, and it seems to work. It doesn't give me any errors, and it allows drag/drop of the entries.
BUT, it never updates my datasource. I have tried putting breakpoints on the update events, both on the reorder list, but also on the datasource, none fires.
What could i possibly do wrong, to achieve this?
Here's my code, just in case:
[Code]....
[Code]....
View 3 Replies
Sep 1, 2010
I cannot get the asyncfileupload to fire the uploadcomplete event at all.
I did a test:Protected Sub AsyncFileUpload1_UploadedComplete(ByVal sender As Object, ByVal e As AjaxControlToolkit.AsyncFileUploadEventArgs) Handles AsyncFileUpload1.UploadedComplete
View 7 Replies
Oct 7, 2010
I need a Slider that will only postback when the slider has been moved. Can this be achieved with SliderExtender?
I have a TextBox with autopostback=true, within an updatepanel within a usercontrol. The TextBox is extended by SliderExtender (default settings).
The TextBox's TextChanged event fires perfectly when the slider is moved (MouseUp - standard extender setting). The aspx page is partially posted back, and all is well.
However, if another usercontrol on the same aspx page causes a partial postback, the SliderExtender causes the TextChanged event to be raised - for no aparent reason. This is causing problems.
Is it possible to prevent postback unless the slider has actually been moved?!
View 2 Replies
Jun 9, 2010
I have a CollapsiblePanelExtender (ext1) with a second CollapsiblePanelExtender (ext2) within it. Is it possible that when ext1 is extnended that it checks the value of a dropdownlist within ext1 and depending on the value of the ddl then extend ext2?
View 1 Replies
Oct 6, 2010
I'm trying to do a similar thing -- I have a long form and in part of it, I have an updatepanel.
Inside the updatepanel I have:5 dropdowns (using the CascadingDropdown functionality)One AddProduct ButtonGrid or Repeater (haven't set it up yet)
I want the following to happen:I have the AddProduct Button disabled initially, but I want it to be enabled once the 5th dropdown is selected (so OnSelectedIndexChanged).If they click the AddProduct button, I want it to populate a Grid or Repeater.So far I am just trying to show what the selection was in a label... but nothing happens. I have an OnSelectedIndexChanged function for the last dropdown, so it enables the button, but that doesn't appear to get called. Previously, before disabling the button, I tried updating the label on button click -- and nothing there either.
It just seems like, because they are in the updatepanel, those callbacks never happen. I also do have UpdateMode = Conditional and I have both items in the triggers list.
View 2 Replies