IIS7 Running .net 2.0 Application Under .net 4.0 CLR

Apr 4, 2011

I want my .net2.0 webservice application to run on IIS7.0 under CLR4.0, Is this possible simply creating an apppool with Classic,.netframework 4.0 settings and pointing my app to this pool? I have tried this and it works fine, but want to confirm on right track?

View 2 Replies


Similar Messages:

Running Locally With IIS7?

Jan 3, 2010

This may be obvious to many of you (hopefully!) I have a site under asp.net created using Visual Web Developer 2008 and MSSQL 2007 (all express editions)All ok so far.My PSP requires the addition of a couple of traditional ASP 'screens' to redirect payments to them. I cannot run this under VWD2008 development server as .asp are not allowed, so am looking to move to running it locally under IIS7 which is turned on.How do I alter the site to run on the IIS7 instance?

View 3 Replies

Set The MaxAllowedContentLength To 500MB While Running On IIS7?

Oct 26, 2010

I changed the maxAllowedContentLength to

<security>
<requestFiltering>
<requestLimits maxAllowedContentLength="5024000000" />
</requestFiltering>
</security>

In my web.config, but when running on IIS7 I get this error:

The 'maxAllowedContentLength' attribute is invalid. Not a valid unsigned integer

but when I run in the VS server it run normally without any errors.

How to config my website to allow upload files with 500MB size, without this problem on IIS7?

View 1 Replies

Is It Possible To Determine The Managed Pipeline IIS7 Is Running Under?

May 30, 2010

Is it possible to determine the managed pipeline IIS7 is running under in ASP.NET?

View 1 Replies

Errors Running .NET 1.1 On IIS7 (applicationHost.config)?

Jan 11, 2011

I am trying to port an existing ASP.Net 1.1 website to another web server that currently runs IIS7 and a number of websites that target either .Net 2.0, 3.5 or 4.0. All other sites continue to work perfectly. Unfortunately, I can only browse static files on the newly imported site. If I try to access any of the Features in IIS7 for the new sit

View 1 Replies

IIS7.5 Running Both 32bit And 64bit Websites?

Sep 22, 2010

Can someone tell me if its possible to run both a 64bit compiled web site and a 32bit compiled website on the same IIS7.5 machine. The core OS would be Windows 2008 R2 64bit. I looked around and can only find how to switch the appPools to 32 or 64. But the question I want answered is can you have one appPool 32bit and another 64bit?

View 1 Replies

Web Forms :: Server 2008 R2 - IIS7 And Running .exe Files

Dec 9, 2010

I'm using ASP.net 3.5 to run a .exe with Process.Start(). It works fine if I use the host that's built-in to VS2008, WinServer 2003 but if I use IIS7 it no longer runs. I am using the following code.

Process proc =
new
Process();
proc.StartInfo = psi;
proc.StartInfo.FileName = "cmd.exe";
proc.StartInfo.Arguments = args;
proc.Start();

View 2 Replies

Security - Restrict Access To A Specific URL, Running On IIS7

Jun 10, 2010

I am deploying a public ASP.NET website on an IIS7 web farm.

The application runs on 3 web servers and is behind a firewall.

We want to create a single page on the website that is accessible only to internal users. It is primarily used for diagnostics, trigger cache expiry, etc.

/admin/somepage.aspx

What is the best way to control access to this page? We need to:

Prevent all external (public) users from accessing the URL. Permit specific internal users to access the page, only from certain IPs or networks.

Should this access control be done at the (a) network level, (b) application level, etc.?

View 3 Replies

Iis7 - URL Routing In .Net Webforms Running Under The Classic .NET AppPool?

Dec 29, 2010

Does anybody knows if it is possible to make URL routing in a ASP.Net webforms website that is running under the Classic .NET AppPool.

I've tried a few things here, but it just works when I switch from Classic AppPool to Default AppPool.

** the web site MUST run under Classic AppPool.

View 2 Replies

Running IIS7 In Classic Mode Does Affect MVC Output Caching

Feb 25, 2010

I have a need to run an application in classic mode for backwards compatibility with a specific application, and am trying to understand what kind of impact that will have on the performance of an MVC application that is running on the site. If we put a few static file maps (for .js, .css, .png, etc) above the ASP.NET wildcard map to reduce the amount of processing by the ASP.NET handler, will we be approaching the integrated mode in terms of performance?

The thing i'm primarily concerned with is any effect this might have on output caching. I understand that integrated mode might (?) allow for the output cache to handle non ASP.NET content, but that isn't really a concern. We're more interested in ensuring that the MVC application has full use of the output cache. Empirically i've found that the two configurations operate on par when things go well, but if the page references resources that are not available, the integrated mode tends to fail much more quickly than the classic mode (e.g. 500 ms vs 10 seconds), reducing 'hang time' on the page load.

View 1 Replies

SQL Reporting :: Blank Reports Are Displayed When Running The Project Through IIS7?

Nov 6, 2010

i have one problem in executing the ssrs reports..

i've developed one project for that project there are some SSRS reports which are deployed

in path ( "http://localhost/reports/") it is working fine...

when i run through the project and press F5 ( i.e execute) the reports

are displaying correct with full of content in that...

now i want to host that project.. so i've created one virtual folder named as proj in IIS7..

and i've assigned the project to that..

when i execute from IE7 and type the path http://localhost/proj then the main page is displayed

and when i click the button print then it is showing the empyt report with only the toolbar above

no content are there in reports ...

but when the run the project i.e F5 then the report is displayed with full of content...

View 1 Replies

WCF / ASMX :: WcfDataService Error "HTTP 500" Using IIS7 Running Under Windows 7

Feb 15, 2011

I have created an entity model and linked service which works fine when testing from within VStudio 2010 but when I publish and browse to svc I get an HTTP 500 error. Thought this might be linked to db credentials (anonymouss access) so set this to fixed sa login as test , no success. Also have set all IIS app pool to use v4.0 of .net. Using IIS7 running under Windows 7, svc entityaccessrule set to "*".

View 1 Replies

MVC :: Running 2.0 App On Localhost IIS7 Gives "HTTP Error 403.14 - Forbidden"

Nov 29, 2010

I've written a small MVC application and am having trouble deploying it to localhost. I use the publish feature when I browse http://localhost this is what I get: HTTP Error 403.14 - Forbidden The Web server is configured to not list the contents of this dir A sample aspx page is rendered correctly.

I've tried the aspnet_regiis -r I've made sure ASP.NET is installed in Windows Features. The web platform installer tells me MVC 2.0 is installed. I did install VS2010 first and then IIS so I suspect that maybe causing problems but in the past aspnet_regiis -r has fixed that.

View 4 Replies

C# - Unloading An Application Can Affect Another Running Application?

Oct 12, 2010

Application domains allow applications to be unloaded separately. My question is how unloading an apllication can crash another application.

View 2 Replies

Deploying An ASP MVC Application To IIS7?

Feb 12, 2010

I've got an ASP MVC (1.0) application. It works fine locally via visual studio and on our dev server which runs IIS6. But when I try to deploy to the Test server (running IIS7 on Windows Server 2008 R2) I get only :"Could not load file or assembly '<ApplicationName>' or one of its dependencies. Access is denied" (where <ApplicationName> is the name of my application). This is followed by a "FileLoadException", a "ConfigurationErrorsException" and two "HttpException" (all with the same message as above)I deployed via publishing to an empty directory, whose contents were then zipped and transferred to the site directory on the test server. If I copy the directories contents to my IIS installation it works fine. I've checked that networkservices has permission to access the site directories and the temporary directories, which were the solutions I found via google,

View 2 Replies

MVC :: Deployment Of An Asp Application In IIS7?

Sep 30, 2010

I want Deploy a MVC2 application in IIS7.

What Can I do?

View 3 Replies

Iis7 - Exception After Publishing Asp.net Web Application

Feb 23, 2011

I have a web application and when I decided to test on IIS 7 i have this Exception when trying to load a couple of pages that uses Entity Framework 4. I use EF 4 with my own CRUD assemblies but sometimes using the EntityDataSource. I have noticed that the problem is not appearing in all my Web Pages but I think in those that I use the EntityDataSource.

Here's the log from a Page:

Unable to load one or more of the requested types. Retrieve the LoaderExceptions property for more information.

mscorlib

System.Type[] GetTypes(System.Reflection.RuntimeModule)

at System.Reflection.RuntimeModule.GetTypes(RuntimeModule module)
at System.Reflection.RuntimeModule.GetTypes()
at System.Reflection.Assembly.GetTypes()
at System.Data.Metadata.Edm.ObjectItemConventionAssemblyLoader.LoadTypesFromAssembly()
at System.Data.Metadata.Edm.ObjectItemAssemblyLoader.Load()
at System.Data.Metadata.Edm.AssemblyCache.LoadAssembly(Assembly assembly, Boolean loadReferencedAssemblies, ObjectItemLoadingSessionData loadingData)
at System.Data.Metadata.Edm.AssemblyCache.LoadAssembly(Assembly assembly, Boolean loadReferencedAssemblies, KnownAssembliesSet knownAssemblies, EdmItemCollection edmItemCollection, Action`1 logLoadMessage, Object& loaderCookie, Dictionary`2& typesInLoading, List`1& errors)
at System.Data.Metadata.Edm.ObjectItemCollection.LoadAssemblyFromCache(ObjectItemCollection objectItemCollection, Assembly assembly, Boolean loadReferencedAssemblies, EdmItemCollection edmItemCollection, Action`1 logLoadMessage)
at System.Data.Metadata.Edm.ObjectItemCollection.ExplicitLoadFromAssembly(Assembly assembly, EdmItemCollection edmItemCollection, Action`1 logLoadMessage)
at System.Data.Metadata.Edm.MetadataWorkspace.ExplicitLoadFromAssembly(Assembly assembly, ObjectItemCollection collection, Action`1 logLoadMessage)
at System.Data.Metadata.Edm.MetadataWorkspace.LoadFromAssembly(Assembly assembly, Action`1 logLoadMessage)
at System.Web.UI.WebControls.EntityDataSourceView.ConstructContext()
at System.Web.UI.WebControls.EntityDataSourceView.ExecuteSelect(DataSourceSelectArguments arguments)
at System.Web.UI.DataSourceView.Select(DataSourceSelectArguments arguments, DataSourceViewSelectCallback callback)

................it's not complete but I guess you can see the latest breadcumb...

Just for more info i post another page problem.

Unable to load one or more of the requested types. Retrieve the LoaderExceptions property for more information.

mscorlib

System.Type[] GetTypes(System.Reflection.RuntimeModule)

at System.Reflection.RuntimeModule.GetTypes(RuntimeModule module)
at System.Reflection.RuntimeModule.GetTypes()
at System.Reflection.Assembly.GetTypes()
at System.Data.Metadata.Edm.ObjectItemConventionAssemblyLoader.LoadTypesFromAssembly()
at System.Data.Metadata.Edm.ObjectItemAssemblyLoader.Load()
at System.Data.Metadata.Edm.AssemblyCache.LoadAssembly(Assembly assembly, Boolean loadReferencedAssemblies, ObjectItemLoadingSessionData loadingData)
at System.Data.Metadata.Edm.AssemblyCache.LoadAssembly(Assembly assembly, Boolean loadReferencedAssemblies, KnownAssembliesSet knownAssemblies, EdmItemCollection edmItemCollection, Action`1 logLoadMessage, Object& loaderCookie, Dictionary`2& typesInLoading, List`1& errors)
at System.Data.Metadata.Edm.ObjectItemCollection.LoadAssemblyFromCache(ObjectItemCollection objectItemCollection, Assembly assembly, Boolean loadReferencedAssemblies, EdmItemCollection edmItemCollection, Action`1 logLoadMessage)
at System.Data.Metadata.Edm.ObjectItemCollection.ExplicitLoadFromAssembly(Assembly assembly, EdmItemCollection edmItemCollection, Action`1 logLoadMessage)
at System.Data.Metadata.Edm.MetadataWorkspace.ExplicitLoadFromAssembly(Assembly assembly, ObjectItemCollection collection, Action`1 logLoadMessage)
at System.Data.Metadata.Edm.MetadataWorkspace.LoadFromAssembly(Assembly assembly, Action`1 logLoadMessage)
at System.Web.UI.WebControls.EntityDataSourceView.ConstructContext()
at System.Web.UI.WebControls.EntityDataSourceView.ExecuteSelect(DataSourceSelectArguments arguments)
at System.Web.UI.DataSourceView.Select(DataSourceSelectArguments arguments, DataSourceViewSelectCallback callback)
at System.Web.UI.WebControls.DataBoundControl.PerformSelect()
at System.Web.UI.WebControls.BaseDataBoundControl.DataBind()
at System.Web.UI.WebControls.FormView.DataBind()
at System.Web.UI.WebControls.BaseDataBoundControl.EnsureDataBound()
at System.Web.UI.WebControls.FormView.EnsureDataBound()
at System.Web.UI.WebControls.CompositeDataBoundControl.CreateChildControls()
at System.Web.UI.Control.EnsureChildControls()
at System.Web.UI.Control.PreRenderRecursiveInternal()
at System.Web.UI.Control.PreRenderRecursiveInternal()
at System.Web.UI.Control.PreRenderRecursiveInternal()
at System.Web.UI.Page.ProcessRequestMain(Boolean includeStagesBeforeAsyncPoint, Boolean includeStagesAfterAsyncPoint)

I think its the EDM problem but I can't get through.
I should mention that in my development pc is working all perfectly!!!

My controls are DevExpress but I dont think this should play any role!

[EDIT]

Forgot to mention that I use Self tracking Template with the Entities.tt in a separate assembly!

[EDIT 2]

On my local Windows 7 IIS works OK! It's Windows Server 2008 I can't get it done!

View 1 Replies

IIS7 Folder Permissions For Web Application?

Mar 28, 2010

I am using windows authentication without impersonation on my company's intranet website with IIS7.

Under IIS7, what account is used to access the folder which contains my web app using these settings?

Would it be IIS_IUSRS? Or NETWORK SERVICE? Or another I don't know about?

View 1 Replies

IIS7 Serve Same Application Under Different Directories?

Nov 3, 2010

I wanna serve my application in ISS to be accessed from many different URL's on my web server.

eg.

http://example.com/test1
http://example.com/test2

Both these URL's get served by the same application.

I do NOT however want to just create new virtual applications to the application, because it stuffs up the user membership roles. The users and their roles must exist accross the two URL's.

View 1 Replies

Iis7 - Application Can Contain Multiple AppDomains ?

Jan 12, 2010

Application Pool may contain multiple worker processes (w3wp.exe) ?Application Pool may contain multiple Asp.NET Applications ?Asp.NET assigns one ThreadPool per AppDomain ?One AppDomain only contain one Web Application Instance but Application can contain multiple AppDomains ?

Edit : These questions are related to IIS 6x or higher, in which App Domains are available.

View 1 Replies

MVC :: Deploying Application To IIS7 - HTTP Error 404.3

Mar 15, 2010

I have published my site using Visual Stuido's 2008 publish feature. I have then copied these files to a windows 2008 web server with IIS7 installed, it also has .net 3.5 sp1 and MVC installed In IIS I added the site using the 'Add a new site' right click option and then pointed this at the directory my site files are located in, I used the default application pool and it is set to integrated. Then when I attempt to browse I got the error message The Web server is configured to not list the contents of this directory. So I added Default.aspx to the default document list and I then get the following error message

HTTP Error 404.3 - Not Found The page you are requesting cannot be served because of the extension configuration. If the page is a script, add a handler. If the file should be downloaded, add a MIME map. Has anyone got any ideas on what I do next ? I have read lots of articles on this online but most are confusing and dont explain the solution in simple terms Surely it should be pretty straightforard to just deploy an MVC website to IIS7

View 4 Replies

Iis7 - Batch Create Asp.net Application Folders IIS 7?

Mar 10, 2011

We have a set of about 30-50 users who periodically need an ASP.net (version 4) application directory created for them.

As these numbers grow, manually creating an application directory for each user becomes cumbersome on IIS 7.

Is there a way to create these application folders using a batched/scripted/automated mechanism of some kind?

Ideally we'd like to provide input parameters of a file that contains a batch of application-names, and have the script automatically create the application directories in IIS.

View 3 Replies

Iis7 - 3.5 Application With Multiple Web.config Files (IIS 7)

Nov 28, 2010

We are working on a web application that creates more web applications.Each web application will have to get a Url Rewrite rule (URL REWRITE MODULE 2.0).As far as I know, there's no way to add such rules without modifying the web.config file (am I right??).So my plan was to work with multiple web.config partial files. One main .config file, and lots of .config files per application (every file will contain it's web application url rewrite rules).This way sounds a little bit messy, but I can't think of anything else, and suggestions will be welcomed.

View 1 Replies

Iis7 - Should Set .NET Application Pool To Auto-recycle

Mar 3, 2011

I have a number of ASP.NET (4.0) web applications that appear to leak (a small amount) of memory during each request. It is such a small amount, that for most use-cases, it will not grow to become a problem for weeks or even months at a time. I generally try to be good with closing any connections managed by the application, avoiding state-variables (or instance variables for my singleton), etc. My question is this - is this normal behavior for ASP.NET applications? I had turned off the default (IIS 7) behavior of recycling the app pool after 20 minutes of being idle. I do this since the application takes a few minutes to build its internal cache, and I want to avoid negatively impacting the user experience (and having them wait for the application to start when they issue the request).

View 1 Replies

MVC :: Identity.Name Is Disposed In IIS7 Application Thread?

Jun 16, 2010

I don't know if it's IIS, ASP.NET or IIS7 related. I take a chance here, if you think I'm in the wrong forum, just tell me which one I should post to.

I have made the smallest demo project to illustrate my problem. You can download the sources

Here

Visual Studio 2008, .NET 3.5, IIS7, Windows 7 Ultimate 32 bits. The IIS Website is configured
ONLY for Windows Authentication in an Integreated pipeline app pool (DefaultAppPool).

Here's the problem. I have an Asp.NET MVC 2 application. In an action, I start a thread. The View returns.

The thread is doing it's job... but it needs to access Thread.CurrentPrincipal.Identity.Name

BANG

The worker process of IIS7 stops. I have a window that says: "Visual Studio Just-In-Time Debugger An unhandled exception ('System.Object.DisposedException') occured in w3wp.exe [5524]"

I checked with the debugger and the Thread.CurrentPrincipal.Identity is valid, but the Name property is disposed.

If I put a long wait in the action before it returns the view, then the Thread can do it's job and the Identity.Name is not disposed. So I think the Name gets disposed when the view is returned.

For the sake of the discussion, here's the code that the thread runs (but you can also download the demo project. The link is on top of this post):

[Code]....

Here's the code that starts the thread

[Code]....

View 3 Replies







Copyrights 2005-15 www.BigResource.com, All rights reserved