Feb 9, 2010
I have a simple web site with two pages. One displays a list of files, and the other streams a file when it's clicked in the list. All was fine in production for 6 months, but now I have to move the site to Windows 2008/IIS7. I have it mostly working, but the files don't open properly (in Firefox) because my content-type header is being ignored. On the production site (IIS6) the headers are (using Fiddler):
HTTP/1.1 200 OK
Date: Tue, 09 Feb 2010 16:00:51 GMT
Server: Microsoft-IIS/6.0
X-Powered-By: ASP.NET
X-AspNet-Version: 2.0.50727
Content-Disposition: attachment; filename="myfile__foo.pdf"
Content-Length: 236841
Cache-Control: no-cache, no-store
Pragma: no-cache
Expires: -1
Content-Type: application/octet-stream
but on the test IIS7 server I get:
HTTP/1.1 200 OK
Cache-Control: private
Content-Length: 236841
Content-Type: text/html; charset=utf-8
Server: Microsoft-IIS/7.5
X-AspNet-Version: 2.0.50727
Content-Disposition: attachment; filename="myfile__foo.pdf"
Fiddler also reports a protocol violation and says "Content-length mismatch: Response Header claimed 236841 bytes, but server sent 238378 bytes."
My code looks like this:
[code]....
View 1 Replies
Similar Messages:
Jun 18, 2010
I have a working solution on an IIS6, which I made using this guide: FLV Flash video streaming with ASP.NET 2.0, IIS and HTTP handler
The app is basically a FLV Player, but streaming is essential to it.
Now, one of our customers is running IIS7 and the streaming doesn't work.
View 2 Replies
Feb 4, 2010
I have an asp.net web page to serve large file downloads to users.
The page is hosted on IIS7, Windows Server 2008.
The strange thing is that users can download at good speeds (2MB/s) when I don't add a content-length response header but as soon as I add this header, download speed drops to somewhere around 35kbps/s.
This is the code:
[code]...
Of course I can leave the content-length out but the user will not know how big the file is and how long the download will take...which is annoying.
View 1 Replies
May 7, 2010
I'm getting this message when going to a web app that accesses my service.
"The content type text/html of the response message does not match the content type of the binding (text/xml; charset=utf-8)..."
The thing is, it happens once in a while even when no changes have been made to the service or the web app. And I can make it go away most of the time by going directly to the .svc?wsdl page in my browser and then coming back to the web app.
View 2 Replies
Sep 3, 2010
If a browser requests http://site.com/?q=abc
and gets a 301 redirect response to location http://site.com/?q=ABC (note case of querystring)
Is it possible for the browser to ignore the difference in case and re-request http://site.com/?q=abc, thus causing an infinite redirect loop?That's the scenario that appears to be happening according to the IIS logs. It seems to be isolated to Internet Explorer with some variation of the Ask toolbar installed (based on user-agent values). I even installed the Ask toolbar, but have not been able to recreate this scenario in any way.
I can't post the source code, but for those that want something, here's the general logic:
Page_Load(object sender, EventArgs e)
{
var q = Request.QueryString["q"];[code]...
As you can see, if this page is requested with ?q=abc it will be redirected once, but then it'll render as usual because the redirect goes to ?q=ABC.Is there any scenario where the browser (specifically IE with the Ask toolbar) could ignore the case of the redirect location, causing an endless loop?
View 2 Replies
Mar 24, 2011
I was wondering if there was any way to ignore content if a contentplaceholder doesn't exist?
View 2 Replies
Jul 12, 2010
I want to remove any mapped routes for files with a certain file extension.
RouteTable.Routes.Ignore("{root}.hello");
Works for any file that has the extension .hello in the root directory, however as soon as i go into any subfolders the 'ignore' rule isn't applied.
Ive tried lots of different combination's, but can't seem to get one that doesn't throw a compiler exception, or not work?
View 2 Replies
Dec 9, 2010
I want to store .flv files in the database and not in the file system.
This is what I can do right now: Successfully convert .wmv and .mpeg to .flv with ffmpeg. Store images in SQL Server and show them on my page with an httphandler. Same with .avi and .mpeg videos. (It's up to the user's software if he can view it though) Play .flv files in the browser if the file is located in the file system and not in the database.
What I can't do is: Stream .flv videos to JW Player directly from the database. (Stored as binary data)
I've searched the internet for two days now but I can't get it to work. It feels as if I'm almost there though. The JW Player opens up and starts to "buffer", but nothing happens.
I know there's no easy answer but if anyone has done this before, or something similar, I'd like to know how you did. I feel I've got too much code to post it all here.
View 3 Replies
Aug 30, 2010
i am trying to read file from a stream.
and i am using stream.read method to read the bytes. So the code goes like below
FileByteStream.Read(buffer, 0, outputMessage.FileByteStream.Length)
Now the above gives me error because the last parameter "outputMessage.FileByteStream.Length" returns a long type value but the method expects an integer type.
View 1 Replies
Apr 1, 2010
Is it at all possible to use IIS7's rewrite capability in web.config to strip a particular HTTP header from a client request?We have an application that makes an HTTP POST to our website, and apparently the request contains the HTTP Expect header. Previously this was not a problem, but we've switched hosts and now the site is returning HTTP error 417 Expectation failed. So the real solution is to fix the software so it doesn't send the Expect header, but that can't happen soon enough for the folks in charge, who'd like to come up with an immediate web-based fix.I've used ISAPI_Rewrite before and I've read that it can strip a header, and the new host claimed they had ISAPI installed... but that seems to have been a lie, as I cannot get it to work, and support's only response on the subject is "use IIS7 Rewrite instead."
View 2 Replies
Dec 22, 2010
I have a site that dynamically loads website contents based on domain host name, served from IIS7. All of the domains share a cached collection of settings. The settings are being flushed from the cache on almost every page request, it seems. This is verified by logging the times at which the Cache value is null and reloaded from SQL. This codes works as expected on other servers and sites. Is it possible that ASP.NET Cache is being stored separately for each domain host name?
View 3 Replies
Jan 7, 2011
I need to add an expires header to my .less files in IIS7. Not quite sure how to do it.
View 2 Replies
Jan 16, 2010
First, a little background. I have written a custom HTTP compression module for ASP.NET. My development machine has Windows 7 Ultimate, which comes with IIS7. My production environment uses IIS6.
The problem I'm having is, Resource Expert Droid (redbot.org) tells me that I need to add a header to my response to properly support compression: "Vary: Accept-Encoding"
On IIS7 in integrated mode, it works properly. However, in classic mode, which is how my application ultimately runs, I cannot get my code to output this header using any of Response.AppendHeader(), Response.Cache.SetVaryByCustom(), or Response.Cache.VaryByHeaders.
View 1 Replies
Oct 21, 2010
I am attempting to set the content-type of an asp.net .ashx file to text/plain.
When I run this through the ASP.NET Development Server, the content-type is properly set. When I serve it through IIS7, however, the content-type (and any other header values I set) don't come through (it came through as text/html).
The only value set in the HTTP Response Headers section of IIS Manager is the X-Powered-By attribute. I tried setting the content-type here, but that didn't work. But if I removed the X-Powered-By attribute, it was removed from the header.
[code]....
View 1 Replies
Jan 20, 2011
I have an httpmodule and it has a handler for OnEndRequest. I am trying to write the HttpContext.Response.OutputStream to a file. I am trying to use the Read method of it. But when it is called the exception message i get is "Specified method is not supported". So i am not able to do what i want that is, write the response to a file on the disk. I am able to write the HttpContext.Request.InputStream to a file using its Read method which i do in a handler for OnBeginRequest.
View 2 Replies
Feb 4, 2011
I need to get the mime types in an IIS7 environment. They should be in:
<configuration>
<system.webServer>
<staticContent>
<mimeMap...
As I understand it, in IIS7 if I can get to it I should see both custom additions in my web.config as well as the mime types defined in the IIS manager at the machine level.
I don't understand how to get to this data. I have messed with the configurationmanager but I am not getting anywhere. I can get a section names system.webServer but I don't see any of the actual data as colleciton of properties or as xml.
View 1 Replies
Feb 22, 2011
I have an excel file in my Response Output stream. I can Open the stream as a file after a prompt, but it doesn't seem I can save it directly to a specified folder on my client.
View 1 Replies
Feb 24, 2011
I have a domain which is receiving quite a few hits per day and have been asked if I can serve the static content from a subdomain. As the site is quite extensive and already written, I was wondering if there is any way I can use URL rewriting to change:
www.example.com/image.gif
to
static.example.com/image.gif
I have a solution which works using 301 redirects but from what I understand, this is counter productive as 2 requests will have to be made per image. I don't really want to go through all the aspx pages and css to hard code the new url as it will cause problems further down the line - some parts of the site are still being developed and static content could change at any time. I tried using rewrite (as opposed to redirect) to change the url but it came out something like:
http://www.example.com/http://static.example.com/image.gif
How would you achieve this? I have full access to dns and the server (win 2008r2 / IIS 7.5) so can make any changes if url rewriting is not the answer.
View 1 Replies
Mar 3, 2010
I have a custom implementation of Application_PreRequestHandlerExecute which is applying a deflate/gzip filter to the response. However, on IIS7, this is failing on my "script generator" pages. These aspx pages take in Query String values and return a custom bit of script, changing the response type to text/javascript. I think it is failing because of the way iis7 uses mime types, but I'm unsure how to fix it short of turning all compressio off.
View 1 Replies
Sep 28, 2010
I have a website on IIS 7. This website has a HttpModule with an AuthorizeRequest event handler. This event does not fire for CSV files and I can access the file without logging in, I guess this is because IIS7 is not configured to require form autentication for CSV files.
View 2 Replies
Nov 28, 2010
We are working on a web application that creates more web applications.Each web application will have to get a Url Rewrite rule (URL REWRITE MODULE 2.0).As far as I know, there's no way to add such rules without modifying the web.config file (am I right??).So my plan was to work with multiple web.config partial files. One main .config file, and lots of .config files per application (every file will contain it's web application url rewrite rules).This way sounds a little bit messy, but I can't think of anything else, and suggestions will be welcomed.
View 1 Replies
Jul 28, 2010
I have an ASP.NET master page which references a #include file as follows:
<!--#include virtual="/includes/scripts.inc"-->
I have modified the file /includes/scripts.inc but the changes do not show up in pages. What needs to be done so modifications will be reflected? I need to avoid the following: restarting the server restarting IIS modifying web.config (doesn't appear to have any effect)
pretty much anything that causes the app domain to restart Any other options? Is there a setting which affects how long IIS caches #include files?
View 4 Replies
Oct 25, 2010
We'd like to restrict the maximum upload file size in our web site. We've already set the appropriate limits in our web.config. The problem we're encountering is if a really large file (1 GB, for example) is uploaded, the entire file is uploaded before a server-side error is generated, and the type of the error is different whether the file is huge or not. Is there a way to detect the size of a pending file upload before the actual upload takes place?
Here's my relevant web.config settings that restrict requests to 16 MB:
[Code]....
Update:
I know that client-side technologies like Flash can detect file sizes before upload, but we need a server-side workaround because we're wanting to target platforms that have no Flash/Java/ActiveX/Silverlight support. I believe that IIS or ASP.NET has a bug that's allowing large files to be uploaded despite the limits, so I've filed a bug here.
Would an ISAPI extension give me more control over request processing than HTTP modules and handlers, such as allowing me to abort an upload if the Content-Length header is seen to be larger than the allowed limit?
Update 2:
Sigh. Microsoft has closed the bug I filed as a duplicate but has provided no additional information. Hopefully they didn't just drop the ball on this.
View 2 Replies
Mar 12, 2010
We've got a process currently which causes ASP.NET websites to be redeployed. The code is itself an ASP.NET application. The current method, which has worked for quite a while, is simply to loop over all the files in one folder and copy them over the top of the files in the webroot.
The problem that's arisen is that occasionally files end up being in use and hence can't be copied over. This has in the past been intermittent to the point it didn't matter but on some of our higher traffic sites it happens the majority of the time now. I'm wondering if anyone has a workaround or alternative approach to this that I haven't thought of. Currently my ideas are:
Simply retry each file until it works. That's going to cause errors for a short time though which isn't really that good. Deploy to a new folder and update IIS's webroot to the new folder. I'm not sure how to do this short of running the application as an administrator and running batch files, which is very untidy.
Does anyone know what the best way to do this is, or if it's possible to do #2 without running the publishing application as a user who has admin access (Willing to grant it special privileges, but I'd prefer to stop short of administrator)? Edit Clarification of infrastructure... We have 2 IIS 7 webservers in an NLB running their webroots off a shared NAS (To be more clear, they're using the exact same webroot on the NAS). We do a lot of deploys, to the point where any approach we can't automate really won't be viable.
View 6 Replies
Mar 3, 2011
I want to upload a Excel file into database. But File name and File Type is not specific. that means excel file may be created in Office 2003
or Office 2007 or Office 2010. Now I knew that Connection string is diffrent for each format. But how i can recognize the File Format ?
I want to fetch data from all type of Excel files. I am using FileUpload control for uploading Excel.
View 4 Replies